NOAA ERDDAP
Easier access to scientific data

Brought to you by NOAA NMFS SWFSC ERD    

ERDDAP > tabledap > Make A Graph ?

Dataset Title:  Saildrone Arctic 2021 OCS Single Beam Delay Mode 2Hz ASVCO2 Data, drone 1030 Subscribe RSS
Institution:  NOAA/PMEL   (Dataset ID: sd1030_arctic_2021_2hz)
Range: longitude = -172.21739 to 150.18784°E, latitude = 50.558647 to 64.22847°N, time = 2021-08-08T00:00:00.00Z to 2021-10-08T23:59:59.50Z
Information:  Summary ? | License ? | FGDC | ISO 19115 | Metadata | Background (external link) | Subset | Data Access Form
 
Graph Type:  ?
X Axis: 
Y Axis: 
Color: 
-1+1
 
Constraints ? Optional
Constraint #1 ?
Optional
Constraint #2 ?
       
       
       
       
       
 
Server-side Functions ?
 distinct() ?
? ("Hover here to see a list of options. Click on an option to select it.Hover here to see a list of options. Click on an option to select it.Hover here to see a list of options. Click on an option to select it.Hover here to see a list of options. Click on an option to select it.")
 
Graph Settings
Marker Type:   Size: 
Color: 
Color Bar:   Continuity:   Scale: 
   Minimum:   Maximum:   N Sections: 
Draw land mask: 
Y Axis Minimum:   Maximum:   
 
(Please be patient. It may take a while to get the data.)
 
Optional:
Then set the File Type: (File Type information)
and
or view the URL:
(Documentation / Bypass this form ? )
    Click on the map to specify a new center point. ?
Zoom: 
Time range:    |<   -       
[The graph you specified. Please be patient.]

 

Things You Can Do With Your Graphs

Well, you can do anything you want with your graphs, of course. But some things you might not have considered are:

The Dataset Attribute Structure (.das) for this Dataset

Attributes {
 s {
  latitude {
    String _CoordinateAxisType "Lat";
    Float64 _FillValue NaN;
    Float64 actual_range 50.5586458, 64.22846963576676;
    String axis "Y";
    Float64 colorBarMaximum 90.0;
    Float64 colorBarMinimum -90.0;
    String device_name "VectorNav Hull IMU (100041582)";
    String firmware "0.5.0.2";
    String installed_date "2021-07-07T01:34:43.757935Z";
    Float64 installed_height 0.34;
    String ioos_category "Location";
    String long_name "Latitude";
    Float64 missing_value NaN;
    String model_name "VN-300";
    String model_product_page "https://www.vectornav.com/products/vn-300";
    String nominal_sampling_schedule "Always on";
    String serial_number "100041582";
    String standard_name "latitude";
    String units "degrees_north";
    Float64 update_period 50.0;
    String vendor_name "VectorNav";
  }
  longitude {
    String _CoordinateAxisType "Lon";
    Float64 _FillValue NaN;
    Float64 actual_range -172.21738594088743, 150.1878312;
    String axis "X";
    Float64 colorBarMaximum 180.0;
    Float64 colorBarMinimum -180.0;
    String device_name "VectorNav Hull IMU (100041582)";
    String firmware "0.5.0.2";
    String installed_date "2021-07-07T01:34:43.757935Z";
    Float64 installed_height 0.34;
    String ioos_category "Location";
    String long_name "Longitude";
    Float64 missing_value NaN;
    String model_name "VN-300";
    String model_product_page "https://www.vectornav.com/products/vn-300";
    String nominal_sampling_schedule "Always on";
    String serial_number "100041582";
    String standard_name "longitude";
    String units "degrees_east";
    Float64 update_period 50.0;
    String vendor_name "VectorNav";
  }
  time {
    String _CoordinateAxisType "Time";
    Float64 actual_range 1.6283808e+9, 1.6337375995e+9;
    String axis "T";
    String calendar "gregorian";
    String ioos_category "Time";
    String long_name "time in seconds";
    String standard_name "time";
    String time_origin "01-JAN-1970 00:00:00";
    String time_precision "1970-01-01T00:00:00.00Z";
    String units "seconds since 1970-01-01T00:00:00Z";
  }
  trajectory {
    Float32 _FillValue NaN;
    Float32 actual_range 1030.0, 1030.0;
    String cf_role "trajectory_id";
    String comment "A trajectory is a single deployment of a drone";
    String long_name "Trajectory/Drone ID";
  }
  INSTRUMENT_STATE {
  }
  ASVCO2_GENERAL_ERROR_FLAGS {
    UInt32 _FillValue 4294967295;
    UInt32 actual_range 0, 0;
    String ancillary_variable "INSTRUMENT_STATE";
    Float64 colorBarMaximum 50.0;
    Float64 colorBarMinimum 0.0;
    String comment "Bit field of error flags. See manual for details";
    String device_name "PMEL ASVCO2 (ASV1009)";
    String firmware "v1.8-3-gbbd4f8e";
    String installed_date "2021-07-08T16:10:59.030308Z";
    Float64 installed_height 0.2;
    String long_name "ASVCO2 Quality flags";
    String model_name "Gen2";
    String nominal_sampling_schedule "30s on, 3570s off";
    String serial_number "ASV1009";
    String units "bitvector";
    String vendor_name "PMEL";
  }
  ASVCO2_ZERO_ERROR_FLAGS {
    UInt32 _FillValue 4294967295;
    UInt32 actual_range 0, 0;
    String ancillary_variable "INSTRUMENT_STATE";
    Float64 colorBarMaximum 50.0;
    Float64 colorBarMinimum 0.0;
    String comment "Bit field of zero flags. See manual for details";
    String device_name "PMEL ASVCO2 (ASV1009)";
    String firmware "v1.8-3-gbbd4f8e";
    String installed_date "2021-07-08T16:10:59.030308Z";
    Float64 installed_height 0.2;
    String long_name "ASVCO2 Zero flags";
    String model_name "Gen2";
    String nominal_sampling_schedule "30s on, 3570s off";
    String serial_number "ASV1009";
    String units "bitvector";
    String vendor_name "PMEL";
  }
  ASVCO2_SPAN_ERROR_FLAGS {
    UInt32 _FillValue 4294967295;
    UInt32 actual_range 0, 0;
    String ancillary_variable "INSTRUMENT_STATE";
    Float64 colorBarMaximum 50.0;
    Float64 colorBarMinimum 0.0;
    String comment "Bit field of span flags. Most common is 0x0400 (1024) indicating span gas is out. See manual for details";
    String device_name "PMEL ASVCO2 (ASV1009)";
    String firmware "v1.8-3-gbbd4f8e";
    String installed_date "2021-07-08T16:10:59.030308Z";
    Float64 installed_height 0.2;
    String long_name "ASVCO2 Span flags";
    String model_name "Gen2";
    String nominal_sampling_schedule "30s on, 3570s off";
    String serial_number "ASV1009";
    String units "bitvector";
    String vendor_name "PMEL";
  }
  ASVCO2_SECONDARYSPAN_ERROR_FLAGS {
    UInt32 _FillValue 4294967295;
    UInt32 actual_range 0, 0;
    String ancillary_variable "INSTRUMENT_STATE";
    Float64 colorBarMaximum 50.0;
    Float64 colorBarMinimum 0.0;
    String comment "Bit field of secondary span flags. See manual for details";
    String device_name "PMEL ASVCO2 (ASV1009)";
    String firmware "v1.8-3-gbbd4f8e";
    String installed_date "2021-07-08T16:10:59.030308Z";
    Float64 installed_height 0.2;
    String long_name "ASVCO2 Secondary Span flags";
    String model_name "Gen2";
    String nominal_sampling_schedule "30s on, 3570s off";
    String serial_number "ASV1009";
    String units "bitvector";
    String vendor_name "PMEL";
  }
  ASVCO2_EQUILIBRATEANDAIR_ERROR_FLAGS {
    UInt32 _FillValue 4294967295;
    UInt32 actual_range 0, 0;
    String ancillary_variable "INSTRUMENT_STATE";
    Float64 colorBarMaximum 50.0;
    Float64 colorBarMinimum 0.0;
    String comment "Bit field of equilibration and air flags. See manual for details";
    String device_name "PMEL ASVCO2 (ASV1009)";
    String firmware "v1.8-3-gbbd4f8e";
    String installed_date "2021-07-08T16:10:59.030308Z";
    Float64 installed_height 0.2;
    String long_name "ASVCO2 Equilibration and Air flags";
    String model_name "Gen2";
    String nominal_sampling_schedule "30s on, 3570s off";
    String serial_number "ASV1009";
    String units "bitvector";
    String vendor_name "PMEL";
  }
  ASVCO2_RTC_ERROR_FLAGS {
    UInt32 _FillValue 4294967295;
    UInt32 actual_range 0, 0;
    String ancillary_variable "INSTRUMENT_STATE";
    Float64 colorBarMaximum 50.0;
    Float64 colorBarMinimum 0.0;
    String comment "Bit field of real time clock flags. See manual for details";
    String device_name "PMEL ASVCO2 (ASV1009)";
    String firmware "v1.8-3-gbbd4f8e";
    String installed_date "2021-07-08T16:10:59.030308Z";
    Float64 installed_height 0.2;
    String long_name "ASVCO2 RTC flags";
    String model_name "Gen2";
    String nominal_sampling_schedule "30s on, 3570s off";
    String serial_number "ASV1009";
    String units "bitvector";
    String vendor_name "PMEL";
  }
  ASVCO2_FLOWCONTROLLER_FLAGS {
    UInt32 _FillValue 4294967295;
    UInt32 actual_range 0, 0;
    String ancillary_variable "INSTRUMENT_STATE";
    Float64 colorBarMaximum 150.0;
    Float64 colorBarMinimum 0.0;
    String comment "Bit field of flow controller flags. See manual for details";
    String device_name "PMEL ASVCO2 (ASV1009)";
    String firmware "v1.8-3-gbbd4f8e";
    String installed_date "2021-07-08T16:10:59.030308Z";
    Float64 installed_height 0.2;
    String long_name "ASVCO2 Flow control flags";
    String model_name "Gen2";
    String nominal_sampling_schedule "30s on, 3570s off";
    String serial_number "ASV1009";
    String units "bitvector";
    String vendor_name "PMEL";
  }
  ASVCO2_LICOR_FLAGS {
    UInt32 _FillValue 4294967295;
    UInt32 actual_range 0, 0;
    String ancillary_variable "INSTRUMENT_STATE";
    Float64 colorBarMaximum 150.0;
    Float64 colorBarMinimum 0.0;
    String comment "Bit field of licor CO2 flags. See manual for details";
    String device_name "PMEL ASVCO2 (ASV1009)";
    String firmware "v1.8-3-gbbd4f8e";
    String installed_date "2021-07-08T16:10:59.030308Z";
    Float64 installed_height 0.2;
    String long_name "ASVCO2 LICOR flags";
    String model_name "Gen2";
    String nominal_sampling_schedule "30s on, 3570s off";
    String serial_number "ASV1009";
    String units "bitvector";
    String vendor_name "PMEL";
  }
  CO2DETECTOR_TEMP_ASVCO2 {
    Float64 _FillValue NaN;
    Float64 actual_range 3.323, 18.348;
    String ancillary_variable "INSTRUMENT_STATE";
    Float64 colorBarMaximum 40.0;
    Float64 colorBarMinimum -10.0;
    String comment "Detector temperature";
    String device_name "LI-COR Gas Analyzer (CGA-5178)";
    String firmware "1.0.4";
    String installed_date "2021-07-08T16:11:06.402015Z";
    String long_name "CO2 Detector Temperature ASVCO2";
    Float64 missing_value NaN;
    String model_name "LI-830";
    String model_product_page "https://www.licor.com/env/support/LI-850/manuals.html";
    String nominal_sampling_schedule "30s on, 3570s off";
    String sampling_frequency "2 Hz";
    String serial_number "CGA-5178";
    String units "degree_C";
    String vendor_name "LI-COR";
  }
  CO2DETECTOR_PRESS_UNCOMP_ASVCO2 {
    Float64 _FillValue NaN;
    Float64 actual_range 92.05, 104.17;
    String ancillary_variable "INSTRUMENT_STATE";
    String comment "Pressure within sample stream (not atmospheric pressure). Bias NOT applied";
    String device_name "LI-COR Gas Analyzer (CGA-5178)";
    String firmware "1.0.4";
    String installed_date "2021-07-08T16:11:06.402015Z";
    String last_pressure_bias_measured "2021-05-06T00:00:00Z";
    String long_name "CO2 Detector Pressure Uncompensated ASVCO2";
    Float64 missing_value NaN;
    String model_name "LI-830";
    String model_product_page "https://www.licor.com/env/support/LI-850/manuals.html";
    String nominal_sampling_schedule "30s on, 3570s off";
    String pressure_bias "0.1 kPa";
    String sampling_frequency "2 Hz";
    String serial_number "CGA-5178";
    String units "kPa";
    String vendor_name "LI-COR";
  }
  CO2DETECTOR_PRESS_ASVCO2 {
    Float64 _FillValue NaN;
    Float64 actual_range 92.15, 104.27;
    String ancillary_variable "INSTRUMENT_STATE";
    String comment "Pressure within sample stream (not atmospheric pressure). Bias applied";
    String device_name "LI-COR Gas Analyzer (CGA-5178)";
    String firmware "1.0.4";
    String installed_date "2021-07-08T16:11:06.402015Z";
    String last_pressure_bias_measured "2021-05-06T00:00:00Z";
    String long_name "CO2 Detector Pressure ASVCO2";
    Float64 missing_value NaN;
    String model_name "LI-830";
    String model_product_page "https://www.licor.com/env/support/LI-850/manuals.html";
    String nominal_sampling_schedule "30s on, 3570s off";
    String pressure_bias "0.1 kPa";
    String sampling_frequency "2 Hz";
    String serial_number "CGA-5178";
    String units "kPa";
    String vendor_name "LI-COR";
  }
  CO2_ASVCO2 {
    Float64 _FillValue NaN;
    Float64 actual_range -2.579, 585.997;
    String ancillary_variable "INSTRUMENT_STATE";
    String ASVCO2_secondaryspan_concentration "1994.25 micromol mol-1";
    String ASVCO2_secondaryspan_serialnumber "CB11490";
    String ASVCO2_span_concentration "499.53 micromol mol-1";
    String ASVCO2_span_serialnumber "JB03791";
    String comment "CO2 concentration in sample stream, at sample RH (not dry)";
    String device_name "LI-COR Gas Analyzer (CGA-5178)";
    String firmware "1.0.4";
    String installed_date "2021-07-08T16:11:06.402015Z";
    String last_ASVCO2_validation "2021-04-28T00:00:00Z";
    String long_name "CO2 ASVCO2";
    Float64 missing_value NaN;
    String model_name "LI-830";
    String model_product_page "https://www.licor.com/env/support/LI-850/manuals.html";
    String nominal_sampling_schedule "30s on, 3570s off";
    String sampling_frequency "2 Hz";
    String serial_number "CGA-5178";
    String units "micromol mol-1";
    String vendor_name "LI-COR";
  }
  RH_ASVCO2 {
    Float64 _FillValue NaN;
    Float64 actual_range 55.904, 62.31;
    String ancillary_variable "INSTRUMENT_STATE";
    Float64 colorBarMaximum 100.0;
    Float64 colorBarMinimum 0.0;
    String comment "relative humidity of partially dried sample";
    String device_name "Sensiron Digital Humidity Sensor (ASV1009)";
    String installed_date "2021-08-03T17:18:29.855284Z";
    String long_name "Relative Humidity within sample stream of partially dried sample";
    Float64 missing_value NaN;
    String model_name "SHT35";
    String model_product_page "https://www.sensirion.com/en/environmental-sensors/humidity-sensors/digital-humidity-sensors-for-various-applications/";
    String nominal_sampling_schedule "30s on, 3570s off";
    String sampling_frequency "2 Hz";
    String serial_number "ASV1009";
    String standard_name "relative_humidity";
    String units "percent";
    String vendor_name "Sensiron";
  }
  RH_TEMP_ASVCO2 {
    Float64 _FillValue NaN;
    Float64 actual_range 1.88, 17.486;
    String ancillary_variable "INSTRUMENT_STATE";
    Float64 colorBarMaximum 40.0;
    Float64 colorBarMinimum -10.0;
    String device_name "Sensiron Digital Humidity Sensor (ASV1009)";
    String installed_date "2021-08-03T17:18:29.855284Z";
    String long_name "Temperature of the sample at the relative humidity sensor";
    Float64 missing_value NaN;
    String model_name "SHT35";
    String model_product_page "https://www.sensirion.com/en/environmental-sensors/humidity-sensors/digital-humidity-sensors-for-various-applications/";
    String nominal_sampling_schedule "30s on, 3570s off";
    String sampling_frequency "2 Hz";
    String serial_number "ASV1009";
    String units "degree_C";
    String vendor_name "Sensiron";
  }
  CO2DETECTOR_RAWSAMPLE_ASVCO2 {
    UInt32 actual_range 5501697, 6377672;
    String ancillary_variable "INSTRUMENT_STATE";
    Float64 colorBarMaximum 100.0;
    Float64 colorBarMinimum 0.0;
    String comment "Licor raw detector sample counts";
    String device_name "LI-COR Gas Analyzer (CGA-5178)";
    String firmware "1.0.4";
    String installed_date "2021-07-08T16:11:06.402015Z";
    String long_name "CO2 Detector Raw Sample Counts ASVCO2";
    UInt32 missing_value 0;
    String model_name "LI-830";
    String model_product_page "https://www.licor.com/env/support/LI-850/manuals.html";
    String nominal_sampling_schedule "30s on, 3570s off";
    String sampling_frequency "2 Hz";
    String serial_number "CGA-5178";
    String units "count";
    String vendor_name "LI-COR";
  }
  CO2DETECTOR_RAWREFERENCE_ASVCO2 {
    UInt32 actual_range 5119416, 5301860;
    String ancillary_variable "INSTRUMENT_STATE";
    Float64 colorBarMaximum 100.0;
    Float64 colorBarMinimum 0.0;
    String comment "Licor raw detector reference counts";
    String device_name "LI-COR Gas Analyzer (CGA-5178)";
    String firmware "1.0.4";
    String installed_date "2021-07-08T16:11:06.402015Z";
    String long_name "CO2 Detector Raw Reference Counts ASVCO2";
    UInt32 missing_value 0;
    String model_name "LI-830";
    String model_product_page "https://www.licor.com/env/support/LI-850/manuals.html";
    String nominal_sampling_schedule "30s on, 3570s off";
    String sampling_frequency "2 Hz";
    String serial_number "CGA-5178";
    String units "count";
    String vendor_name "LI-COR";
  }
  O2_ASVCO2 {
    Float64 _FillValue NaN;
    Float64 actual_range 14.063, 38.31;
    String ancillary_variable "INSTRUMENT_STATE";
    Float64 colorBarMaximum 100.0;
    Float64 colorBarMinimum 0.0;
    String comment "This oxygen measurement is made in the ASVCO2 equilibrated air stream. NOAA/PMEL has found that the oxygen does not come to complete equilibrium with seawater during the EPON and EPOFF states so any rapid changes in oxygen do not get properly captured using this instrument. We use the oxygen data only as a qualitative sense of the biology. It is not a quantitative measure.";
    String device_name "Maxtec Diagnostic O2 Sensor (EK59499036)";
    String installed_date "2021-07-08T16:11:12.688637Z";
    String long_name "Diagnostic Oxygen ASVCO2";
    Float64 missing_value NaN;
    String model_name "Max-250";
    String model_product_page "https://www.maxtec.com/product/sensing/fio2/max-250/";
    String nominal_sampling_schedule "30s on, 3570s off";
    String sampling_frequency "2 Hz";
    String serial_number "EK59499036";
    String units "percent";
    String vendor_name "Maxtec";
  }
  O2_COEFFICIENT_ASVCO2 {
    Float64 _FillValue NaN;
    Float64 actual_range 0.0, 0.0;
    String ancillary_variable "INSTRUMENT_STATE";
    String device_name "Maxtec Diagnostic O2 Sensor (EK59499036)";
    String installed_date "2021-07-08T16:11:12.688637Z";
    String long_name "Diagnostic Oxygen coefficient from sample loop";
    Float64 missing_value NaN;
    String model_name "Max-250";
    String model_product_page "https://www.maxtec.com/product/sensing/fio2/max-250/";
    String nominal_sampling_schedule "30s on, 3570s off";
    String serial_number "EK59499036";
    String vendor_name "Maxtec";
  }
  XCO2_DRY_SW_MEAN_ASVCO2 {
    Float64 _FillValue NaN;
    Float64 actual_range 204.61, 465.28;
    String ancillary_variable "INSTRUMENT_STATE";
    String ASVCO2_secondaryspan_concentration "1994.25 micromol mol-1";
    String ASVCO2_secondaryspan_serialnumber "CB11490";
    String ASVCO2_span_concentration "499.53 micromol mol-1";
    String ASVCO2_span_serialnumber "JB03791";
    String comment "Calculated per Sutton, A.J., Sabine, C.L., Maenner-Jones, S., Lawrence-Slavas, N., Meinig, C., Feely, R.A., Mathis, J.T., Musielewicz, S., Bott, R., McLain, P.D., Fought, J., Kozyr, A., 2014b. A high-frequency atmospheric and seawater pCO2 data set from 14 open ocean sites using a moored autonomous system. Earth Sys. Sci. Data, 6, doi: 10.5194/essd-6-353-2014, 353-366.";
    String device_name "LI-COR Gas Analyzer (CGA-5178)";
    String firmware "1.0.4";
    String installed_date "2021-07-08T16:11:06.402015Z";
    String installed_height_water "-0.53 m";
    String last_ASVCO2_validation "2021-04-28T00:00:00Z";
    String long_name "xCO2 Dry Seawater Mean ASVCO2";
    Float64 missing_value NaN;
    String model_name "LI-830";
    String model_product_page "https://www.licor.com/env/support/LI-850/manuals.html";
    String nominal_sampling_schedule "30s on, 3570s off";
    String sampling_frequency "2 Hz";
    String serial_number "CGA-5178";
    String units "micromol mol-1";
    String vendor_name "LI-COR";
  }
  XCO2_DRY_AIR_MEAN_ASVCO2 {
    Float64 _FillValue NaN;
    Float64 actual_range 352.53, 413.45;
    String ancillary_variable "INSTRUMENT_STATE";
    String ASVCO2_secondaryspan_concentration "1994.25 micromol mol-1";
    String ASVCO2_secondaryspan_serialnumber "CB11490";
    String ASVCO2_span_concentration "499.53 micromol mol-1";
    String ASVCO2_span_serialnumber "JB03791";
    String comment "Calculated per Sutton, A.J., Sabine, C.L., Maenner-Jones, S., Lawrence-Slavas, N., Meinig, C., Feely, R.A., Mathis, J.T., Musielewicz, S., Bott, R., McLain, P.D., Fought, J., Kozyr, A., 2014b. A high-frequency atmospheric and seawater pCO2 data set from 14 open ocean sites using a moored autonomous system. Earth Sys. Sci. Data, 6, doi: 10.5194/essd-6-353-2014, 353-366.";
    String device_name "LI-COR Gas Analyzer (CGA-5178)";
    String firmware "1.0.4";
    String installed_date "2021-07-08T16:11:06.402015Z";
    String installed_height_air "0.60 m";
    String last_ASVCO2_validation "2021-04-28T00:00:00Z";
    String long_name "xCO2 Dry Air Mean ASVCO2";
    Float64 missing_value NaN;
    String model_name "LI-830";
    String model_product_page "https://www.licor.com/env/support/LI-850/manuals.html";
    String nominal_sampling_schedule "30s on, 3570s off";
    String sampling_frequency "2 Hz";
    String serial_number "CGA-5178";
    String units "micromol mol-1";
    String vendor_name "LI-COR";
  }
  CO2DETECTOR_ZERO_COEFFICIENT_ASVCO2 {
    Float64 _FillValue NaN;
    Float64 actual_range 0.82263625, 0.82621515;
    String ancillary_variable "INSTRUMENT_STATE";
    String ASVCO2_secondaryspan_concentration "1994.25 micromol mol-1";
    String ASVCO2_secondaryspan_serialnumber "CB11490";
    String ASVCO2_span_concentration "499.53 micromol mol-1";
    String ASVCO2_span_serialnumber "JB03791";
    String device_name "LI-COR Gas Analyzer (CGA-5178)";
    String firmware "1.0.4";
    String installed_date "2021-07-08T16:11:06.402015Z";
    String long_name "CO2 Detector Zero Calibration Coefficient, CO2kzero";
    Float64 missing_value NaN;
    String model_name "LI-830";
    String model_product_page "https://www.licor.com/env/support/LI-850/manuals.html";
    String nominal_sampling_schedule "30s on, 3570s off";
    String serial_number "CGA-5178";
    String vendor_name "LI-COR";
  }
  CO2DETECTOR_SPAN_COEFFICIENT_ASVCO2 {
    Float64 _FillValue NaN;
    Float64 actual_range 0.66840505, 0.7388355;
    String ancillary_variable "INSTRUMENT_STATE";
    String ASVCO2_secondaryspan_concentration "1994.25 micromol mol-1";
    String ASVCO2_secondaryspan_serialnumber "CB11490";
    String ASVCO2_span_concentration "499.53 micromol mol-1";
    String ASVCO2_span_serialnumber "JB03791";
    String device_name "LI-COR Gas Analyzer (CGA-5178)";
    String firmware "1.0.4";
    String installed_date "2021-07-08T16:11:06.402015Z";
    String long_name "CO2 Detector Span Calibration Coefficient CO2kspan, Span Offset";
    Float64 missing_value NaN;
    String model_name "LI-830";
    String model_product_page "https://www.licor.com/env/support/LI-850/manuals.html";
    String nominal_sampling_schedule "30s on, 3570s off";
    String serial_number "CGA-5178";
    String vendor_name "LI-COR";
  }
  CO2DETECTOR_SECONDARY_COEFFICIENT_ASVCO2 {
    Float64 _FillValue NaN;
    Float64 actual_range -0.01301503, -0.01301503;
    String ancillary_variable "INSTRUMENT_STATE";
    String ASVCO2_secondaryspan_concentration "1994.25 micromol mol-1";
    String ASVCO2_secondaryspan_serialnumber "CB11490";
    String device_name "LI-COR Gas Analyzer (CGA-5178)";
    String firmware "1.0.4";
    String installed_date "2021-07-08T16:11:06.402015Z";
    String last_secondaryspan_calibrated "2021-02-22T00:00:00Z";
    String last_secondaryspan_temperaturedependantslope "2021-02-22T00:00:00Z";
    String long_name "CO2 Detector Secondary Span Calibration Coefficient, CO2kspan2, Span Slope";
    Float64 missing_value NaN;
    String model_name "LI-830";
    String model_product_page "https://www.licor.com/env/support/LI-850/manuals.html";
    String nominal_sampling_schedule "30s on, 3570s off";
    String secondaryspan_calibrated_rh "2.25 percent";
    String secondaryspan_calibrated_spanconcentration "502.76 micromol mol-1";
    String secondaryspan_calibrated_spanserialnumber "JA02448";
    String secondaryspan_calibrated_temperature "22.609 degrees_c";
    String secondaryspan_temperaturedependantslope "-0.00213378 degrees_c-1";
    String secondaryspan_temperaturedependantslopefit "0.966 R^2";
    String serial_number "CGA-5178";
    String vendor_name "LI-COR";
  }
 }
  NC_GLOBAL {
    String acknowledgement "If you use these data in publications or presentations, please acknowledge the Moored Carbon and the Engineering Project Office of NOAA/PMEL. Also, we would appreciate receiving a preprint and/or reprint of publications utilizing the data for inclusion in our bibliography. Relevant publications should be sent to: Moored Carbon Project Office, NOAA/PMEL/OCRD, 7600 Sand Point Way NE, Seattle, WA 98115 or emailed to: adrienne.sutton@noaa.gov";
    String area "Bering and Chukchi Sea";
    String cdm_data_type "Trajectory";
    String cdm_trajectory_variables "trajectory";
    String citation "Please cite Sabine et. al. (2020) when using this dataset.  Sabine, C., A.J. Sutton, K. McCabe, N. Lawrence-Slavas, S.R. Alin, R.A. Feely, R. Jenkins, S. Maenner, C. Meinig, J. Thomas, E. van Ooijen, A. Passmore, and B. Tilbrook (2020): Evaluation of a new carbon dioxide system for autonomous surface vehicles. J. Atmos. Oceanic Tech., 37(8), 1305–1317, doi: 10.1175/JTECH-D-20-0010.1";
    String contributor_email "Stacy.maenner@noaa.gov; Nathan.anderson@noaa.gov; Noah.lawrence-slavas@noaa.gov";
    String contributor_name "Stacy Maenner; Nathan Anderson; Noah Lawrence-Slavas";
    String contributor_role "PMEL/Carbon; PMEL/OCS; PMEL/EDD";
    String Conventions "CF-1.6, ACDD-1.3, COARDS";
    String creator_email "Stacy.maenner@noaa.gov";
    String creator_name "Saildrone";
    String creator_url "http://pmel.noaa.gov";
    String data_mode "delay-mode";
    String date_created "2022-02-08T21:39:24.807629Z";
    String description "Saildrone NetCDF Format";
    String drone_id "1030";
    Float64 Easternmost_Easting 150.1878312;
    String featureType "Trajectory";
    String funding_source "NOAA/IOOS OTT";
    Float64 geospatial_lat_max 64.22846963576676;
    Float64 geospatial_lat_min 50.5586458;
    String geospatial_lat_units "degrees_north";
    Float64 geospatial_lon_max 150.1878312;
    Float64 geospatial_lon_min -172.21738594088743;
    String geospatial_lon_units "degrees_east";
    String history 
"Saildrone
2024-12-11T15:36:07Z (local files)
2024-12-11T15:36:07Z https://data.pmel.noaa.gov/generic/tabledap/sd1030_arctic_2021_2hz.das";
    String id "183494";
    String infoUrl "http://pmel.noaa.gov";
    String institution "NOAA/PMEL";
    Float64 interval 0.5;
    String keywords "air, arctic, asvco2, ASVCO2_EQUILIBRATEANDAIR_ERROR_FLAGS, ASVCO2_FLOWCONTROLLER_FLAGS, ASVCO2_GENERAL_ERROR_FLAGS, ASVCO2_LICOR_FLAGS, ASVCO2_RTC_ERROR_FLAGS, ASVCO2_SECONDARYSPAN_ERROR_FLAGS, ASVCO2_SPAN_ERROR_FLAGS, ASVCO2_ZERO_ERROR_FLAGS, atmosphere, atmospheric, beam, calibration, carbon, carbon dioxide, co2, CO2_ASVCO2, CO2DETECTOR_PRESS_ASVCO2, CO2DETECTOR_PRESS_UNCOMP_ASVCO2, CO2DETECTOR_RAWREFERENCE_ASVCO2, CO2DETECTOR_RAWSAMPLE_ASVCO2, CO2DETECTOR_SECONDARY_COEFFICIENT_ASVCO2, CO2DETECTOR_SPAN_COEFFICIENT_ASVCO2, CO2DETECTOR_TEMP_ASVCO2, CO2DETECTOR_ZERO_COEFFICIENT_ASVCO2, co2kspan, co2kspan2, co2kzero, coefficient, control, counts, data, delay, detector, diagnostic, dioxide, dried, drone, dry, earth, Earth Science > Atmosphere > Atmospheric Water Vapor > Humidity, environmental, equilibration, flags, flow, humidity, instrument, INSTRUMENT_STATE, laboratory, latitude, licor, longitude, loop, marine, mean, mode, noaa, noaa/pmel, O2, O2_ASVCO2, O2_COEFFICIENT_ASVCO2, ocs, offset, oxygen, pacific, partially, pmel, pressure, quality, raw, reference, relative, relative_humidity, RH_ASVCO2, RH_TEMP_ASVCO2, rtc, sample, sampling, science, sea, seawater, secondary, seconds, sensor, single, slope, span, sst, state, stream, surface, temperature, time, trajectory, trajectory/drone, uncompensated, vapor, water, within, xco2, XCO2_DRY_AIR_MEAN_ASVCO2, XCO2_DRY_SW_MEAN_ASVCO2, zero";
    String keywords_vocabulary "GCMD Science Keywords";
    String license "2021 (C) SAILDRONE Inc.  All Rights Reserved.  These Data and any resultant Product are the property of SAILDRONE.  At SAILDRONE's sole discretion, these Data may be used for research or educational activities only. You may not use, share or sell the Data for any other purpose including for commercial purposes, or alternatively, have any unauthorized third party use or sell the Data, either for any research, educational and/or commercial purpose(s), without the express prior consent of SAILDRONE.";
    String mission "Arctic OCS Single Beam 2021";
    String naming_authority "com.saildrone";
    String netcdf_version "4.6.2";
    String nodc_template_version "NODC_NetCDF_Trajectory_Template_v2.0";
    Float64 Northernmost_Northing 64.22846963576676;
    String platform "Saildrone";
    String principal_investigator "Dr. Adrienne Sutton";
    String principal_investigator_email "adrienne.sutton@noaa.gov";
    String principal_investigator_institution "NOAA/PMEL";
    String principal_investigator_url "https://www.pmel.noaa.gov/co2/story/Adrienne+J.+Sutton%2C+Ph.D.";
    String product_version "2";
    String project "ASVCO2 Gen2 IOOS OTT:Technology Transfer of a Surface pCO2 Flux Instrument for Autonomous Platform Applications";
    String QC_indicator "Level 0, Raw Data";
    String qc_manual "No QC Performed";
    String source "Saildrone";
    String sourceUrl "(local files)";
    Float64 Southernmost_Northing 50.5586458;
    String standard_name_vocabulary "CF Standard Name Table v58";
    String subsetVariables "trajectory, INSTRUMENT_STATE";
    String summary "Four Gen6 Saildrone Explorer USVs were launched from Dutch Harbor in August 2021. These USVs were equipped with DT800 single beam sonars. Two of the USVs were equipped with Gen1 ASVCO2 sensors and two were equipped with Gen2 ASVCO2 sensors. The objectives of this mission include mapping contours within the Arctic for uncharted or minimally charted parts of the sea, and performing intercomparisons between the Gen1 and Gen2 ASVCO2 systems in the Arctic environment. If pCO2 is calculated, the TEMP_DEPTH_HALFMETER sensor should be used as the primary sea surface temperature when calculating pCO2.";
    String time_coverage_duration "PT23H59M59.999S";
    String time_coverage_end "2021-10-08T23:59:59.50Z";
    String time_coverage_resolution "PT0.5S";
    String time_coverage_start "2021-08-08T00:00:00.00Z";
    String time_in "hz";
    String title "Saildrone Arctic 2021 OCS Single Beam Delay Mode 2Hz ASVCO2 Data, drone 1030";
    Float64 Westernmost_Easting -172.21738594088743;
    String wmo_id "5801955";
    String wmo_platform_code "5801957";
  }
}

 

Using tabledap to Request Data and Graphs from Tabular Datasets

tabledap lets you request a data subset, a graph, or a map from a tabular dataset (for example, buoy data), via a specially formed URL. tabledap uses the OPeNDAP (external link) Data Access Protocol (DAP) (external link) and its selection constraints (external link).

The URL specifies what you want: the dataset, a description of the graph or the subset of the data, and the file type for the response.

Tabledap request URLs must be in the form
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/datasetID.fileType{?query}
For example,
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/pmelTaoDySst.htmlTable?longitude,latitude,time,station,wmo_platform_code,T_25&time>=2015-05-23T12:00:00Z&time<=2015-05-31T12:00:00Z
Thus, the query is often a comma-separated list of desired variable names, followed by a collection of constraints (e.g., variable<value), each preceded by '&' (which is interpreted as "AND").

For details, see the tabledap Documentation.


 
ERDDAP, Version 2.18
Disclaimers | Privacy Policy | Contact